Voltage Reference Source GX6070 Compatible with MAX6070 for Precision Instrumentation

Time:2024-03-21 Views:777
Precision instrumentation is mainly used to produce, measure the precision amount of equipment and devices, including the amount of precision observation, monitoring, determination, verification, recording, transmission, transformation, display, analysis and processing and control, and the voltage reference source is an indispensable part of the precision instrumentation.
In the voltage reference source selection, it has several very important indicators: supply voltage range, can be directly related to the system‘s power supply design, output voltage hysteresis; consistency; voltage noise, temperature drift and so on. In this paper, we recommend a domestic core technology voltage reference source GX6070, which has a micro-power consumption and very low temperature coefficient and noise, very suitable for precision instrumentation, the following voltage reference source GX6070 applied to medical and other precision instruments advantages:
1.GX6070 power supply reference source for ultra-low noise, low temperature drift voltage reference, using a small 6-pin SOT23 package.
2.GX6070 output voltage of 2.5V, 1/f noise voltage is only 4.8μVpp, the maximum temperature drift is 10ppm/°C. 3.GX6070 can be used for medical and other precision instruments.
3. The GX6070 can operate between 2.7V and 5.5V with an operating current of 230μA and a maximum load current of 10mA.
4.GX6070 provides up to ± 0.04% initial accuracy (A suffix), ± 0.2% initial accuracy (B suffix), low temperature drift and low noise indicators are conducive to improving system accuracy, ideal for high-precision industrial design.
5.GX6070 provides noise filter options to meet the requirements of broadband applications; can also provide 1.25V, 1.8V, 2.048V, 2.5V, 3.0V, 3.3V, 4.096V and 5.0V voltage options.
6. The GX6070 operates in a -40°C to +125°C temperature environment and can be configured with external resistors to freely output any voltage from 1.25V to 5V.
Summary: GX6070 is compatible with MaxicoM‘s MAX6070 and MAX6071, GXSC can provide full technical service and stable supply support, and you can apply for samples if needed.