Replacement AD7606, GX7606 ADC for Industrial Oil Valve Monitoring and Control

Time:2024-08-14 Views:469
Industrial oil valve monitoring system usually consists of three major modules such as digital processing, multiplexed analog receiving end, and oil valve sensor. In oil valve monitoring applications, its multiplexed analog receiving end is the process of sampling and quantization, the performance parameters of the ADC directly affect the accuracy and reliability of monitoring.

Resolution determines the minimum amount of analog signal changes that can be resolved, the higher the resolution, the stronger the ability to detect small signal changes. Conversion speed determines the frequency range of the analog signal that the ADC can process, and for the monitoring of oil valve parameters with fast dynamic changes, a higher conversion speed is required.
The program uses the GXSC eight-channel 16-bit, sampling rate of 200kSPS ADC, because it is the GXSC ADC, so that the program design cost is low, and the data acquisition system is adaptable.

GX7606 is a 16-bit synchronous sampling chip, each chip has eight acquisition channels, can fully meet the requirements of the system for sampling, it has a flexible digital filter, 2.5V reference voltage source, and high-speed parallel and serial interfaces, using a single 5V power supply, no longer need to positive and negative power supplies and support for true bipolar signal input.

Performance Parameters.
1, each channel is built-in analog input clamping protection, analog filters, programmable gain amplifiers
2, with 1MQ analog input impedance input buffer
3, the operating temperature range: -40C to +85 ° C, 5V single analog power supply
4, VDRIVE supply voltage: 2.3V to 5V +30V input register protection, 8KV ESD
5, 2nd order anti-alias analog filters
6, on-chip precision reference source and reference voltage source buffer
7, true bipolar analog input range: ± 10V, ± 5V
8, integrated digital filter oversampling function
9, SNR 86dB (no oversampling) 95dB (64 times oversampling)
10, QFP-64 package 12mmx12mm, can replace the AD7606

Summary: GX7606 high-precision analog-to-digital converter can provide more accurate monitoring results, which can help to detect possible problems with the oil valve in time to ensure stable operation of the system.